RCM Industries · Made in the USA since 1966
Direct-Reading Flow Meters
The RCM Flo-Gage™ reads flow directly from a large 270° analog dial — no transmitter, no power supply, no separate orifice plates. A built-in calibrated nozzle and factory calibration mean it arrives ready to install.
What "Direct-Reading" Means
Most industrial flow meters output a signal — 4–20 mA, pulse, or Modbus — that requires a separate display, controller, or PLC to show a flow rate. The Flo-Gage is different: the differential pressure created by its internal calibrated nozzle drives a mechanical indicator directly. The dial face is printed in the engineering units you specify at order time. You read the flow rate the same way you read a pressure gauge — instantly, with no electronics in the loop.
This makes the Flo-Gage ideal for local monitoring stations, utility metering, process verification, and any location where a simple, reliable visual check is more valuable than a data feed.
Key Design Features
Built-in Calibrated Nozzle
The Flo-Gage uses a precision-machined internal nozzle as the primary flow element. Unlike orifice-plate meters, the nozzle and indicator are a single factory-calibrated assembly — no separate plates, no field calibration required.
270° Analog Dial
A large 3.5″ (90 mm) dial sweeps 270° for easy reading at a distance. The scale is printed directly in engineering units (GPM, SCFM, lb/hr, or others) for the specific fluid and range you ordered.
No External Power Required
The meter is fully mechanical. The differential pressure created by the nozzle drives the indicator directly — no electrical connections, no transmitter, no power supply needed for local indication.
±3% Full-Scale Accuracy
Factory calibration to ±3% of full scale with ±1% repeatability. The 6:1 rangeability lets you read accurately from roughly 15% to 100% of the selected full-scale flow rate.
Available for Liquids, Gases, and Steam
The Flo-Gage family covers the most common industrial flow measurement needs. Each meter is factory-calibrated for the specific fluid and flow range you specify.
Ready to Specify a Direct-Reading Meter?
Tell us your fluid, pipe size, flow range, and operating conditions. We'll confirm the right model and provide pricing and lead time.